Cerabar M



Version

1



Registered Product Information

Manufacturer: Endress+Hauser
Product Name: Cerabar M
Product Description: Absolute/Relative Pressure Transmitter
Protocol: HART
Profile: HART EDD Only
More Information: More Information: Products: PMC41; PMC45; PMP41; PMP45; PMP46; PMP48 Pressure transmitter with ceramic and metal sensors, Overload-resistant and function-monitored. Application The Cerabar M pressure transmitters measure overpressure and absolute pressure in gases, steam, liquids and dusts. Thanks to the modular instrument concept, Cerabar M suits all areas of process engineering. Hygienic connections, threaded connections and flanges (also as diaphragm seals) are available as process connections. Your benefits •Performance characteristics •Reference accuracy better than 0.2% of the set measuring range(optional: non-linearity better than 0.1%) •Configurable measuring range up to TD 10:1 •Long-term stability better than 0.25 % / 3 years •Deployed for pressure monitoring up to SIL 2 as per IEC 61508/IEC61511-1 Sensors •Dry capacitance ceramic sensor (Ceraphire®) for measuring ranges up to 40 bar - overload-resistant, vacuum-proof, stable against alternating load •Piezoresistive sensor with metal diaphragm for measuring ranges up to 400 bar Output signals: 4 to 20 mA, 4 to 20 mA with HART, PROFIBUS PA Housing •With its stainless steel housing with no dead space, Cerabar M meets the hygienic requirements of the food and pharmaceutical industries. •The coated aluminum housing has already stood the test of time in the process industry. •Device versions compliant with ASME-BPE

Registered Product Details

Manufacturer ID (hex): 000011
Device Type ID (hex): 110E
DEV_REV (hex): 1
DD Revision: 1
Technology Version: 5

Registration Information

Registration Authority: FieldComm Group
Registration Status: Registered

Contact Information

Device Support File Usage

FieldComm Group (FCG) makes available to its members and to the public certain device driver (DD) files, in various forms, that have passed certain tests conducted by or through FCG. The DD files are, or are created from, submissions to FCG by FCG members and are provided by FCG AS IS. FCG disclaims all liability for the accuracy, suitability or use of the DD files. Each member creating DD files has its own policies regarding supporting use of those files, and may, for instance support use of DD object code files, but not DeviceInfo or other files. While FCG is under no obligation to provide support for use of any DD files, FCG welcomes all inquiries on the subject and will often be able to assist.