3051S ERS



Version

1



Registered Product Information

Manufacturer: Emerson Electric Co.
Product Name: 3051S ERS
Product Description: Rosemount 3051S Electronic Remote Sensor (ERS) System
Protocol: HART
Profile: HART Field Device
Date: 3/31/2021
More Information: HART Version: HART6 Featuring best-in-class performance and measurement stability, the Rosemount 3051S Electronic Remote Sensor (ERS™) System is engineered with flexible, digital architecture. The ERS System calculates differential pressure electronically using two pressure sensors linked together with an electrical cable. Easy to install, this safety-certified system is engineered for faster response time than traditional systems, providing you with exceptional performance in a wide range applications. Features and benefits: - Provides DP Level measurements with a faster response time than traditional systems - Sensors are independently installed without heat tracing and insulation to offer simple installation - Digital architecture delivers stable measurement for applications with excessive temperature variation - Each sensor can be independently serviced for simplified maintenance - Entire system utilizes a single 2-wire, 4-20 mA HART® loop for straightforward system integration - Graphical interface of device dashboard offers simple configuration, commissioning and troubleshooting - Additional monitoring information of static pressure and sensor module temperature provide improved process insights - SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations

Registered Product Details

Manufacturer ID (hex): 000026
Device Type ID (hex): 265E
DEV_REV (hex): 0x01
DD Revision: 4
Technology Version: 6
Wireless Product: No

Registration Information

Registration Authority: FieldComm Group
Registration Status: Registered

Contact Information

Device Support File Usage

FieldComm Group (FCG) makes available to its members and to the public certain device driver (DD) files, in various forms, that have passed certain tests conducted by or through FCG. The DD files are, or are created from, submissions to FCG by FCG members and are provided by FCG AS IS. FCG disclaims all liability for the accuracy, suitability or use of the DD files. Each member creating DD files has its own policies regarding supporting use of those files, and may, for instance support use of DD object code files, but not DeviceInfo or other files. While FCG is under no obligation to provide support for use of any DD files, FCG welcomes all inquiries on the subject and will often be able to assist.