AUMATIC AC 01.2 / ACExC 01.2 FF H1

Version:
1
2

Registered Product Information

Manufacturer: Auma
Product Name: AUMATIC AC 01.2 / ACExC 01.2 FF H1
Product Description: Electric Actuator / Valve Positioner
Protocol: FOUNDATION Fieldbus
Category: Actuators, Regulators, Positioners
Profile: FOUNDATION Field Device
More Information: The AUMA Foundation Fieldbus interface card facilitates a flawless integration of AUMA actuators in Foundation Fieldbus network systems. It can be installed in both the weatherproof and the explosion proof versions of the Generation .2 AUMATIC actuator controls thus supporting a wide variety of different AUMA actuator types such as multi-turn actuators, part-turn actuators or linear actuators, all suitable for most arduous environments and hazardous areas. Features and Benefits: * Plug and socket connection for easy commissioning and maintenance * One type of actuator controls for various actuator types and different application conditions * Individual universality with unified wiring diagrams, unified connection technology and unified programming for simplified and fast planning, installation and commissioning * Comfortable setting due to elegant operator guidance using the display of local controls * Modular design for full support of all the available functions and features with or without fieldbus interface * Integral diagnosis of the Foundation Fieldbus interface for simple, swift and explicit inspection of the fieldbus network and its configuration via the integral display - including health status of the fieldbus connection, the actual and target block modes of the used function blocks and transducer blocks * Various options for data transmission over the Foundation Fieldbus function blocks to provide the utmost flexibility, best performance and maximum communication efficiency. * Optional: 2nd Foundation Fieldbus interface for galvanically separated, redundant H1 communication to AUMA actuators

Registered Product Details

Manufacturer ID (hex): 0A01FF
Device Type ID (hex): 0001
DEV_REV (hex): 01
DD Revision: 0x01, 0x01(DD5)
FOUNDATION Physical Layer Profile: 113 - Standard-power signaling, bus-powered, non I.S. 115 - Standard-power signaling, bus-powered, energy limited (Ex nL) 511 - Low-power signaling, bus-powered, FISCO I.S.
Stack Manufacturer: Softing AG
FOUNDATION Stack Class: 31PS, 32L
Stack Version: 2.42
Registered Blocks: 1-RB2(e), 8-DO(e),<br>10-DI(e), 2-AO(e),<br>4-AI(e), 1-SC(e),<br>1-IS(e), 1-PID(e)
Other Blocks: 1-PTB(c), 1-DITB(c),<br>1-DOTB(c),<br>1-AITB(c),<br>1-AOTB(c),<br>1-AUMA_CTB(c),<br>1-AUMA_DTB(c)
Registered Features: Alarms and Events Function Block Linking Trending Multi-bit Alert Reporting Field Diagnostics

Registration Information

Registration Authority: FieldComm Group
Registration Status: Registered
Tester Version: 6.0.1
DD/CFF Tester Version: 6.0.1

Contact Information

E-mail: Riester@auma.com
Website: http://www.auma.com