Liquiphant 5x/6x



Version

1



Registered Product Information

Manufacturer: Endress+Hauser
Product Name: Liquiphant 5x/6x
Product Description: Point Level Switch
Protocol: HART
Profile: HART Field Device
Date: 12/15/2021
More Information: Product: Liquiphant FTL51B, FTL62, FTL64; Point level switch for minimum or maximum detection in tanks, containers and piping with all types of liquids, even in hazardous areas Application: Process temperature range: –50 to +150 °C (–58 to +302 °F) Pressures up to 100 bar (1450 psi) Viscosities up to 10000 mPa⋅s Ideal substitute for float switches; reliable function is not affected by flow, turbulence, air bubbles, foam, vibration, solids content or buildup Your benefits: The new Liquiphant introduces a robust point level transmitter that combines numerous benefits: Easiest local or remote operation, condition-based maintenance and smart safety in processes. Intuitive and clear wizard navigation guides the user through the commissioning and verification of the device. The integrated Bluetooth connectivity provides a safe and remote operation. The large display with backlight guarantees excellent readability. Heartbeat Technology offers an on-demand verification and monitoring functions to detect e.g. build-up or abbrasion.

Registered Product Details

Manufacturer ID (hex): 000011
Device Type ID (hex): 11C4
DEV_REV (hex): 0x01
DD Revision: 0x01
Technology Version: 7
Wireless Product: No

Registration Information

Registration Authority: FieldComm Group
Registration Status: Registered

Contact Information

Device Support File Usage

FieldComm Group (FCG) makes available to its members and to the public certain device driver (DD) files, in various forms, that have passed certain tests conducted by or through FCG. The DD files are, or are created from, submissions to FCG by FCG members and are provided by FCG AS IS. FCG disclaims all liability for the accuracy, suitability or use of the DD files. Each member creating DD files has its own policies regarding supporting use of those files, and may, for instance support use of DD object code files, but not DeviceInfo or other files. While FCG is under no obligation to provide support for use of any DD files, FCG welcomes all inquiries on the subject and will often be able to assist.