Manufacturer:
Endress+Hauser
Product Name:
FMR2xx
Product Description:
Microwave
Profile:
HART EDD Only
More Information:
Level-Radar for continuous and non-contact level measurement.
Cost-effective 4 to 20 mA 2-wire technology. Suitable for hazardous
locations.
Application
The Micropilot M is used for continuous, non-contact level measurement of
liquids, pastes, slurries, and solids. The measurement is not affected by
changing media, temperature changes, gas blankets or vapors.
* The FMR230 is especially suited for measurement in buffer and process
tanks.
* The FMR231 has its strengths wherever high chemical compatibility is
required.
* The FMR240 with the small 40 mm (1½") horn antenna is ideally suited
for small vessels. Additionally,it provides an accuracy of ±3 mm (±0.12
in).
* The FMR244 combines the advantages of the horn antenna with high
chemical resistance. The 80 mm (3") horn antenna is used additionally
in solids.
* The FMR245 - highly resistant up to 200 °C (392 °F) and easy to clean.
* The FMR250- Level measurement in tall silos with extremely dusty bulk
solids e.g. cement, raw meal or animal feed up to 200 °C (392 °F), e.g.
clinker or fly ash.
Your benefits
o 2-wire technology, low price: A real alternative to differential
pressure, floats and displacers. 2-wire technology reduces wiring
costs and allows easy implementation into existing systems.
o Non-contact measurement: Measurement is almost independent from
product properties.
o Easy on-site operation via menu-driven alphanumeric display.
o Easy commissioning, documentation and diagnostics via
Endress+Hauser operating software.
o 2 frequency ranges - FMR230/FMR231 in the C-band and
FMR240/244/245 ind the K-band: No compromises, the right frequency
for every application.
o HART or PROFIBUS PA respectively FOUNDATION Fieldbus protocol.
o High temperatures: Suitable for process temperatures up to 200 °C
(392 °F), up to 400 °C (752 °F) with high-temperature antenna.
o Rod antenna with inactive length: Reliable measurement in narrow
nozzles, with condensation and build-up in the nozzle.
o Used for level monitoring (MIN, MAX) up to SIL 2 as per IEC 61508
/ IEC 61511.
o Option: gas-tight feedthrough for FMR230/231/240/245 to improve
the process safety.