Manufacturer:
BERNARD CONTROLS
Product Name:
BERNARD_ACTUATOR
Product Description:
Actuator
Profile:
FOUNDATION Field Device
More Information:
L.BERNARD supplies actuators for use in critical applications such as
nuclear power stations or oil & gas plants. Therefore, our devices are
designed to ensure a high level of reliability and durability even in
very harsh operating conditions such as seismically active areas,
explosive atmospheres or high temperature environments.BERNARD actuators
are designed for ON-OFF and MODULATING operation, multiturn and quarter
turn.The complete range of BERNARD actuators with the INTELLI+ controls
can be connected to Foundation Fieldbus. All controls and signalling are
available for the process through Foundation Fieldbus. A local display
makes commissioning easy including Fieldbus status and in multilanguage.
Moreover, with the INTELLI+ controls and Foundation Fieldbus interface ,
information regarding the operation of motorised valves can now easily be
retrieved by the maintenance /instrumentation team.Number of starts,
operating time, opening and closing torque curves are amongst a number of
available data giving a clear insight of your valve operation and
increase your chances to detect valve problems before they happen!
Manufacturer ID (hex):
004000
Device Type ID (hex):
0001
DEV_REV (hex):
01
DD Revision:
0x01
FOUNDATION Physical Layer Profile:
113 - Standard-power signaling, bus-powered, non I.S.
Stack Manufacturer:
Fieldbus Inc.
FOUNDATION Stack Class:
31PS, 32L
Stack Version:
3.0
Registered Blocks:
1xRB2(E), 1xAO(e), 2xAI(E), 5xDI(e), 4xDO(e), 1xPID(e)
Other Blocks:
1xTB(c )
Registered Features:
Alarms and Events
Function Block Linking
Trending
Registration Authority:
FieldComm Group
Registration Status:
Registered
Tester Version:
5.0.1
DD/CFF Tester Version:
5.0.1
FieldComm Group (FCG) makes available to its members and to the public certain device driver (DD) files, in various forms, that have passed certain tests conducted by or through FCG. The DD files are, or are created from, submissions to FCG by FCG members and are provided by FCG AS IS. FCG disclaims all liability for the accuracy, suitability or use of the DD files. Each member creating DD files has its own policies regarding supporting use of those files, and may, for instance support use of DD object code files, but not DeviceInfo or other files. While FCG is under no obligation to provide support for use of any DD files, FCG welcomes all inquiries on the subject and will often be able to assist.