Manufacturer: Baker Hughes Oilfield Operations LLC
Product Name: FVP
Product Description: Valve Positioner
Profile: FOUNDATION Field Device
More Information: “Device type 1 Rev.4 supports single and double-acting actuators. Double-acting positioners can be identified with a model number FVP110-F2….” Low Power: 16mA of power to run – Free’s up available power on the segment to add future devices One Model Fits All – Mounts on Any Rotary or Any Linear valves Manual Pneumatic override switch – Bypass electronics for valve installation, commissioning, diagnosing On Board Valve Signature & Diagnostic Storage – Easily retrieve diagnostic information and Factory birth certificate Built In Positioning Autotune – Patented For Optimal response regardless of Actuator Size / brand – Delivers Highest signal resolution (0.05% typical) – Increases tightness of control loops regardless of valve size Positioner and Control Valve Health Diagnostics – Avoid Startup Issues by FF warnings from the field device – Measure Valve Health and Performance Without Process Disturbance – Record Of “As Left” Performance

Registered Product Details

Manufacturer ID (hex): 445644
Device Type ID (hex): 0001
DEV_REV (hex): 03
DD Revision: 06
FOUNDATION Physical Layer Profile: 111 - Standard-power signaling, bus-powered, Entity Model I.S. 113 - Standard-power signaling, bus-powered, non I.S.
Stack Manufacturer: Yokogawa/Softing
FOUNDATION Stack Class: 31PS, 32LT
Stack Version: 2.0
Registered Blocks: 1xAO(s), 1xPID(s), 2xDI(s), 1xRB(e)
Other Blocks: 1xOS(c), 1xTB(c)
Registered Features: Alarms and Events Function Block Linking Trending

Registration Information

Registration Authority: FieldComm Group
Registration Status: Registered
Tester Version: 4.01
DD/CFF Tester Version: 4.6

Contact Information

Device Support File Usage

FieldComm Group (FCG) makes available to its members and to the public certain device driver (DD) files, in various forms, that have passed certain tests conducted by or through FCG. The DD files are, or are created from, submissions to FCG by FCG members and are provided by FCG AS IS. FCG disclaims all liability for the accuracy, suitability or use of the DD files. Each member creating DD files has its own policies regarding supporting use of those files, and may, for instance support use of DD object code files, but not DeviceInfo or other files. While FCG is under no obligation to provide support for use of any DD files, FCG welcomes all inquiries on the subject and will often be able to assist.