Manufacturer: Honeywell International
Product Name: SmartLine / STT850
Product Description: Temperature Transmitter
Category: Temperature
Profile: FOUNDATION Field Device
More Information: Honeywell SmartLine Temperature transmitters continue to bring proven “smart” technology to a wide spectrum of temperature measurement applications, that involve critical control as well as safety applications. Built on the SmartLine platform, these devices deliver leading and reliable performance while reducing the total cost of ownership. SmartLine Temperature devices provide comprehensive self-diagnostics for the transmitter as well as the sensor to help users maintain high uptime, meet extensive regulatory requirements, and attain the highest quality standards.   The Honeywell SmartLine STT850 is a high performance Temperature transmitter offering high accuracy and stability over a wide range of process and ambient temperatures. This device is fully tested and compliant with Honeywell Experion ® PKS providing the highest level of compatibility assurance and integration capabilities.   Integration with Honeywell’s Experion PKS offers the following unique advantages through Smart Connection suite. Ø  Transmitter messaging – To enhance safety and productivity through clear identification and assignment of maintenance tasks in the local transmitter display Ø  Maintenance mode indication – To enhance Safety through System initiated command to identify that the device is available for maintenance Ø  FDM Plant Area Views with Health summaries – To reduce the time to identify, diagnose and fix device problems by providing an overview of device health based on user defined groups in the Honeywell Field Device Manager.   SmartLine easily meets the most demanding needs for temperature measurement applications. The device can also provide advanced calculation and control capability via the use of the optional PID, signal characterizer, arithmetic, input selector, and output splitter blocks.   Best in Class Features: Industry leading performance o    Digital Accuracy up to 0.10 Deg C for RTD o    Stability up to 0.01% of URL per year for ten years o    125 mSec update time for single input models o    250 mSec update time for dual input models Reliable measurement o    Built in Galvanic Isolation o    Differential/Averaging/Redundant/Split Range measurements o    Dual Compartment Housing o    Sensor Break detection o    Comprehensive on-board diagnostic capabilities o    Full compliance to SIL 2/3 requirements   Lower Cost of Ownership o    Universal input o    Dual sensor option o    Multiple local display capabilities o    Modular construction o    Polarity insensitive loop wiring

Registered Product Details

Manufacturer ID (hex): 48574C
Device Type ID (hex): 0006
DEV_REV (hex): 01
DD Revision: 0x02, 0x02(DD5), 0x01(CF)
FOUNDATION Physical Layer Profile: 111 - Standard-power signaling, bus-powered, Entity Model I.S. 113 - Standard-power signaling, bus-powered, non I.S. 511 - Low-power signaling, bus-powered, FISCO I.S.
Stack Manufacturer: Softing AG
FOUNDATION Stack Class: 31PS, 32L
Stack Version: 2.42
Registered Blocks: 1-RB2(e), 1-AI(s),<br>1-PID(e), 1-AR(s),<br>1-IS(s), 1-SC(s),<br>1-DI(s), 1-OS(s)
Other Blocks: 3-TB(c)
Registered Features: Alarms and Events Function Block Linking Trending Multi-bit Alert Reporting Block Instantiation Common Software Download Field Diagnostics

Registration Information

Registration Authority: FieldComm Group
Registration Status: Registered
Tester Version: 6.1.1
DD/CFF Tester Version: 6.1.2

Contact Information

Device Support File Usage

FieldComm Group (FCG) makes available to its members and to the public certain device driver (DD) files, in various forms, that have passed certain tests conducted by or through FCG. The DD files are, or are created from, submissions to FCG by FCG members and are provided by FCG AS IS. FCG disclaims all liability for the accuracy, suitability or use of the DD files. Each member creating DD files has its own policies regarding supporting use of those files, and may, for instance support use of DD object code files, but not DeviceInfo or other files. While FCG is under no obligation to provide support for use of any DD files, FCG welcomes all inquiries on the subject and will often be able to assist.