Registered Product Information
Manufacturer:
SMAR
Product Name:
HI302-I 8AI+8HART
Product Description:
HI302-HART/FOUNDATION Fieldbus Gateway
Profile:
FOUNDATION Field Device
More Information:
HI302 - HART/Foundation Fieldbus Gateway
The HI302 is an equipment integrated to System302 which main function is
to interface
HART devices to Foundation Fieldbus systems, allowing the user to perform
maintenance,
calibration, sensor status monitoring, device status, among othe
information. See below
some HI302 features:
* Integral part of System302;
* Tight integration with different system manufacturers due to the use
of standard protpcols such as Foundation Fieldbus and HART;
* 8 HART master channels;
* Optional analog conversion (4-20 mA / Foundation Fieldbus - HI302-I
and Foundation Fieldbus / 4-20 mA - HI302-O);
* Totally integrated to AssetView;
* Easy to poerate due to a uniform system and tools;
* Not-multiplexed and independent HART channels;
* HART Configuration Commands located into the module, allowing HART
messages to be sent through parameters and bypass;
* Suitable for Asset Management systems;
* Compatible configuration of Smar devices embedded in HI302 module,
thus no additional configuration is required.
Registered Product Details
Manufacturer ID (hex):
000302
Device Type ID (hex):
0015
DEV_REV (hex):
05
DD Revision:
0x01
FOUNDATION Physical Layer Profile:
111 - Standard-power signaling, bus-powered, Entity Model I.S.
Stack Manufacturer:
SMAR Equipamentos Industriais Ltda
FOUNDATION Stack Class:
31PS, 32LT
Stack Version:
3.40
Registered Blocks:
1xRB(s), 1xAI(s), 1xMAI(s)
Other Blocks:
8xTB(c)
Registered Features:
Alarms and Events
Function Block Linking
Trending
Registration Information
Registration Authority:
FieldComm Group
Registration Status:
Registered
Tester Version:
4.61
DD/CFF Tester Version:
4.61
Contact Information
Device Support File Usage
FieldComm Group (FCG) makes available to its members and to the public certain device driver (DD) files, in various forms, that have passed certain tests conducted by or through FCG. The DD files are, or are created from, submissions to FCG by FCG members and are provided by FCG AS IS. FCG disclaims all liability for the accuracy, suitability or use of the DD files. Each member creating DD files has its own policies regarding supporting use of those files, and may, for instance support use of DD object code files, but not DeviceInfo or other files. While FCG is under no obligation to provide support for use of any DD files, FCG welcomes all inquiries on the subject and will often be able to assist.