Manufacturer:
KROHNE Messtechnik GmbH
Product Name:
OPTISWIRL 4200
Product Description:
Vortex Flowmeter
Profile:
FOUNDATION Field Device
More Information:
Vortex flowmeters measure gas and steam independent of pressure and
temperature. This applies to wet gases and gas mixtures as well. The
KROHNE OPTISWIRL 4200 has integrated pressure and temperature
compensation. This means that the meter can also accurately measure
operating, standard volume, mass flow and gross/net-heat energy under
changing process conditions.
Vortex flowmeters are suitable for utility metering, for example, in
steam or air circuits, a vortex meter is a cost-effective measurement for
balancing energy consumption.
Highlights
Integrated pressure and temperature compensation
Excellent long-term stability through a robust construction
Highly accurate
Maintenance-free sensor
Robust, fully welded stainless steel construction with excellent
corrosion, pressure and temperature resistance
Advanced Vortex Frequency Detection (AVFD) state-of-the-art technology
for digital signal filtering
Redundant Data Management
FAD (Free Air Delivery) functionality
Gross and net heat calculation to support advanced energy management
Manufacturer ID (hex):
00012C
Device Type ID (hex):
0200
DEV_REV (hex):
01
DD Revision:
0x03(DD4), 0x03(DD5)
FOUNDATION Physical Layer Profile:
111 - Standard-power signaling, bus-powered, Entity Model I.S.
113 - Standard-power signaling, bus-powered, non I.S.
511 - Low-power signaling, bus-powered, FISCO I.S.
Stack Manufacturer:
Softing AG
FOUNDATION Stack Class:
31PS, 32L
Stack Version:
2.60
Registered Blocks:
1-RB2(e), 5-AI(e),<br>1-AO(e), 1-PID(e),<br>2-IT(e)
Other Blocks:
2-TB(c)
Registered Features:
Alarms and Events
Function Block Linking
Trending
Multi-bit Alert Reporting
Field Diagnostics
Registration Authority:
FieldComm Group
Registration Status:
Registered
Tester Version:
6.1.2
DD/CFF Tester Version:
6.3.0
FieldComm Group (FCG) makes available to its members and to the public certain device driver (DD) files, in various forms, that have passed certain tests conducted by or through FCG. The DD files are, or are created from, submissions to FCG by FCG members and are provided by FCG AS IS. FCG disclaims all liability for the accuracy, suitability or use of the DD files. Each member creating DD files has its own policies regarding supporting use of those files, and may, for instance support use of DD object code files, but not DeviceInfo or other files. While FCG is under no obligation to provide support for use of any DD files, FCG welcomes all inquiries on the subject and will often be able to assist.