Prowirl 72



Version

1



Registered Product Information

Manufacturer: Endress+Hauser
Product Name: Prowirl 72
Product Description: Vortex Flowmeter
Category: Flow,Vortex
Profile: FOUNDATION Field Device
More Information: Application For measuring the volume or mass flow of saturated steam and liquids. The instrument calculates steam mass flow using data according to the international standard IAPWS-IF97 (ASME). If the pressure is constant, the instrument is able to put out the mass flow of superheated steam or the mass and volume flow of other gases. With devices with a PROFIBUS-PA or FOUNDATION Fieldbus interface the possibility exists, to read the operating pressure as an input value. For utility and process applications in the chemical, petrochemical, power and district heating industries and in many other branches. Your benefits * Proven robust, capacitive sensor (installed base > 100,000) * Immune to: - Vibration (over 1 g in all axes) - Temperature shock (> 150 K/s) - Dirty media - Water hammer * Process temperature range: - 330° to +750°F (-200° to +400°C) * Connection to all common systems: - HART - PROFIBUS-PA - FOUNDATION Fieldbus * Galvanically isolated frequency output available (for flow, alarm, limit value etc.). * Permanent self-monitoring and diagnosis of electronics and sensor. * Correction of diameter mismatch. * No maintenance, no moving parts, no zero-point drift.

Registered Product Details

Manufacturer ID (hex): 452B48
Device Type ID (hex): 1056
DEV_REV (hex): 01
DD Revision: 0x01
FOUNDATION Physical Layer Profile: 111 - Standard-power signaling, bus-powered, Entity Model I.S. 512 - Low-power signaling, separately powered, FISCO I.S.
Stack Manufacturer: Endress + Hauser
FOUNDATION Stack Class: 31PS, 32L
Stack Version: 2.10
Registered Blocks: 2xAI(e), 1xDO(s), 1xRB(e)
Other Blocks: 5xTB(c)
Registered Features: Alarms and Events Function Block Linking Trending

Registration Information

Registration Authority: FieldComm Group
Registration Status: Registered
Tester Version: 4.51
DD/CFF Tester Version: 4.6

Contact Information

Device Support File Usage

FieldComm Group (FCG) makes available to its members and to the public certain device driver (DD) files, in various forms, that have passed certain tests conducted by or through FCG. The DD files are, or are created from, submissions to FCG by FCG members and are provided by FCG AS IS. FCG disclaims all liability for the accuracy, suitability or use of the DD files. Each member creating DD files has its own policies regarding supporting use of those files, and may, for instance support use of DD object code files, but not DeviceInfo or other files. While FCG is under no obligation to provide support for use of any DD files, FCG welcomes all inquiries on the subject and will often be able to assist.