OKOBUS 18AWG(0.8mm) FF-844 Type-A Cable



Version

NA



Registered Product Information

Manufacturer: Okonite
Product Name: OKOBUS 18AWG(0.8mm) FF-844 Type-A Cable
Product Description: 18AWG or 0.8mm2 / 1-24 Shielded Twisted Pairs
Category: H1 Cable
Profile: FOUNDATION H1 Cable
Date: 3/22/2018
More Information: Shielded Twisted Single and Multi-Pair 300V fieldbus cable Product Features UL Listed as PLTC Power Limited Tray Cable UL Listed as ITC-ER - Instrument Tray Cable/Exposed Run. Type PLTC & Type ITC-ER for use in accordance with NEC articles 727 and 725 Single Pair passes IEEE 1202 vertical tray flame test. Multi-Pairs pass the IEEE 383 and UL 13 vertical tray flame tests. Sunlight Resistant 720hr per UL 1581 Oil resistance pre ICEA S-95-658. -30C to 90C. UL listed for direct burial. Individual pairs are completely isolated. 100% Overall shield coverage. Product Description Conductor: #18AWG(0.8mm2) tinned copper, Class B, stranded per ASTM B-8. Insulation: Cross Linked Polyethylene(X-Olene) 32mils(0.81mm) nominal thickness, 90°C temperature rating per UL 13 and 2250. Conductor Identification: Pigmented orange and blue in pairs, orange conductor numerically printed for group identification. Pair Shield: Aluminum/Polyester tape overlapped to provide 100% coverage, and a Class B tinned copper drain wire, two sizes smaller than the conductor. All multi-pair shields are isolated from each other. Multi-Pair Assembly: Pairs assembled with a left-hand lay. Cable fillers included where required to provide a round cable. Multi-Pair Cable Shield: Aluminum/Polyester tape overlapped to provide 100% coverage, and a Class B strand tinned copper drain wire, same size As conductor. Jacket: Orange, flame-retardant, PVC(Okoseal) per UL 13 and 2250. A rip cord is laid longitudinally under the jacket to facilitate removal. 18AWG ITC-ER Products # of Pairs: Okonite Product Code 1 Pairs: 267-92-4901 2 Pairs: 267-92-4902 4 Pairs: 267-92-4904 6 Pairs: 267-92-4906 8 Pairs: 267-92-4908 12 Pairs: 267-92-4912 16 Pairs: 267-92-4916 20 Pairs: 267-92-4920 24 Pairs: 267-92-4924

Registered Product Details

Cable Listings: Instrument Tray cable (ITC) Power Limited Tray Cable (PLTC)
Application Type: Trunk or Spur
Gauge/Size: 18AWG or 0.8mm2
Number of Pairs: 1-24 Shielded Twisted Pair
Characteristics: Exposed Run Direct Burial UV Resistance Flame Retardancy Wire Insulation Colors: Blue and Orange Mutual Capacitance = 30nF/km Pair Inductance = 760mH/km

Registration Information

Registration Authority: FieldComm Group
Registration Status: Registered

Contact Information