Image
Manufacturer: | ABB |
Product Name: | TTX300 |
Product Description: | Temperature Transmitter |
Protocol: | FOUNDATION Fieldbus |
Category: | Temperature |
Profile: | FOUNDATION Field Device |
More Information: | Temperature Transmitter with Ø Sensor redundancy Ø Sensor drift monitoring Ø Sensor error adjustment Input Ø Resistance thermometers Ø Thermocouples Ø Resistance-type transmitters Ø Voltages, mV voltages Input Functionality Ø 1 or 2 sensors Ø 2 x Pt100 three-wire circuit Output Ø FOUNDATION Fieldbus H1 in accordance with IEC 61158-2 Ø Baud rate 31.25 kbit/s, ITK 5.2 Ø FISCO-compliant in accordance with IEC 60079-27 Ø Device ID: 000320001F Ø Error current signal FDE (Fault Disconnection Electronic) Ø Block Structure o Resource Block o Transducer Block 1 temperature o Transducer Block 2 HMI (LCD) o Transducer Block 3 extended diagnostics o Analog Input 1 PRIMARY_VALUE_1 (sensor 1) o Analog Input 2 PRIMARY_VALUE_2 (sensor 2) o Analog Input 3 PRIMARY_VALUE_3 (calculated value*) o Analog Input 4 SECONDARY_VALUE (reference point temp) o Analog Output optional HMI display (transducer block 2) o Discrete Input 1 extended diagnostics 1 (transducer block 3) o Discrete Input 2 extended diagnostics 2 (transducer block 3) o PID PID controller *Sensor1, sensor2, or difference, or mean LAS (Link Active Scheduler) link master functionality Specific linearization Ø Callendar van Dusen coefficients Ø Table of variate pairs/32 points Continuous sensor monitoring and self-monitoring Ø Supply voltage monitoring Ø Wire break and corrosion monitoring in accordance with NE 89 Ø Extended diagnostics in accordance with NE 107 Device safety in accordance with NE 53 Software write protection, hardware write protection Approvals for explosion protection Ø ATEX, IECEx, Zone 0 Ø FM / CSA Ø GOST Russia Configuration Ø LCD Ø EDD Service interface |
Manufacturer ID (hex): | 000320 |
Device Type ID (hex): | 001F |
DEV_REV (hex): | 01 |
DD Revision: | 0x01, 0x01(DD5) |
FOUNDATION Physical Layer Profile: | 111 - Standard-power signaling, bus-powered, Entity Model I.S. 113 - Standard-power signaling, bus-powered, non I.S. 121 - Low-power signaling, bus-powered, Entity Model I.S. 123 - Low-power signaling, bus-powered, non I.S. 511 - Low-power signaling, bus-powered, FISCO I.S. |
Stack Manufacturer: | Softing AG |
FOUNDATION Stack Class: | 31PS, 32L |
Stack Version: | 2.21 |
Registered Blocks: | 1-RB2(e), 4-AI(e), 1-AO(s), 1-PID(e), 2-DI(e) |
Other Blocks: | 1-AITB(c), 1-AOTB(c), 1-DITB(c) |
Registered Features: | Alarms and Events Function Block Linking Trending |
Registration Authority: | FieldComm Group |
Registration Status: | Registered |
Tester Version: | 5.2.0 |
DD/CFF Tester Version: | 5.2.0 |
E-mail: | https://new.abb.com/contact-centers |
Website: | http://www.abb.com/temperature |