Manufacturer:
KROHNE Messtechnik GmbH
Product Name:
OPTIMASS MFC300
Product Description:
Coriolis Mass Flowmeter
Profile:
FOUNDATION Field Device
More Information:
The OPTIMASS Family of Coriolis mass flowmeters
OPTIMASS 1000 the dual straight tube meter for process control and
standard applications.
OPTIMASS 2000 the dual straight tube meter for bulk flow measurements and
CT applications
OPTIMASS 3000 the low flow bent tube meter with a high safety factor
OPTIMASS 7000 the single straight tube meter for high end and CT
applications
No limits with tube materials
Titanium, Hastelloy, Stainless Steel, Duplex, Super Duplex, or Tantalum
allow straight tube metering for almost any process.
No limits with flow
From 0.3 to 2,300,000 kg/h with a full range of meters for low, normal
and bulk flow applications.
No limits with measured product
High viscosity, particulate matter, inhomogeneous mixtures, normal
entrained air, have little effect on the accuracy of the measurement.
No limits with installation
Support on the process pipe or the meter body, without the need for
accurate positioning. A complete range of process connectors for all
existing and future installations is available.
No limit with electronics
OPTIMASS has been designed with all new electronics, which incorporates
Front End signal processing that is permanently mounted to the meter.
This provides high speed and low noise measurement, as well as remote
connection to the signal converter up to 300 m. Dual redundancy of
configured data, calibration constants etc ease maintenance.
No limits with applications
KROHNE can provide metering solutions whatever your requirement
including: Flow, Density, Concentration and Temperature.
OPTIMASS features
* Adaptive Sensor Technology
* Fully programmable electronics providing a choice of multiple outputs
* Modular signal converter for greater flexibility
* Large size meters with implemented pressure compensation
* Flow handling from 0.3 ... 2,300,000 kg/h (0.011 ... 84,510 Ibs/min)
* Temperature range from -45 °C
+ 150 °C (--49
+302 °F)
* Smooth transition from tube to process pipe
* Hygienic Process Connection System
* Compliance with EHEDG, 3A standards and using FDA approved materials
* 6 Models and 13 sizes with a choice of 4 tube materials
* Approved for hazardous area applications to ATEX, FM and CSA.
* Approved for custody transfer according directive 2004/22/EC (MID)
Adaptive Sensor Technology AST
KROHNE has re-designed the Coriolis flowmeter from the inside out to
produce an instrument that is inherently balanced under all operating
conditions.
The result is a meter that can cope with the most demanding process
conditions and still deliver accurate and reliable measurement time after
time. KROHNEs patented AST design is extremely stable and will
adaptively tune each meter independent of external forces and fluid
density.
Tried and tested technology
To ensure the highest standards of quality and accuracy, all meters in
the OPTIMASS family have been rigorously tested. Series 1000, 2000,
3000, 7000 and 8000 have been comprehensively trialed at major chemical,
pharmaceutical and food and beverage sites in Europe to actively measure
the mass flow of substances such as margarine, coffee extract or
pesticides, oils and acids and are delivering previously unattainable
levels of performance.
Manufacturer ID (hex):
00012C
Device Type ID (hex):
0320
DEV_REV (hex):
03
DD Revision:
0x02, 0x02(DD5)
FOUNDATION Physical Layer Profile:
112 - Standard-power signaling, separately powered, Entity Model I.S.
512 - Low-power signaling, separately powered, FISCO I.S.
Stack Manufacturer:
Softing AG
FOUNDATION Stack Class:
31PS, 32L
Stack Version:
2.21
Registered Blocks:
1-RB(e), 6-AI(s), 3-IT(s), 1-PID(s)
Other Blocks:
1-TB(c)
Registered Features:
Alarms and Events
Function Block Linking
Trending
Multi-bit Alert Reporting
Registration Authority:
FieldComm Group
Registration Status:
Registered
Tester Version:
5.2.0
DD/CFF Tester Version:
5.2.0
FieldComm Group (FCG) makes available to its members and to the public certain device driver (DD) files, in various forms, that have passed certain tests conducted by or through FCG. The DD files are, or are created from, submissions to FCG by FCG members and are provided by FCG AS IS. FCG disclaims all liability for the accuracy, suitability or use of the DD files. Each member creating DD files has its own policies regarding supporting use of those files, and may, for instance support use of DD object code files, but not DeviceInfo or other files. While FCG is under no obligation to provide support for use of any DD files, FCG welcomes all inquiries on the subject and will often be able to assist.